Return to IndexĬlick on Rectifiers to see or display the Summary, Configuration or Efficiency Manager. The number of Phases that the Eltek rack has is configured here.


Return to IndexĬlick on the Mains tab, this will then display the Mains Summary tab. ThisEltek slide is of version 3.2Ĭlick on the EVENT LOG tab, this will display the LATEST xx EVENTS tab, click on this tab which then displays all the recent events, alarms. Note: If RBS is installed and utilising -48V to +24V DC converter then the ‘CONVERTER FAIL’ Alarm must be assigned to ‘Alarm output1’ (DC Urgent) How to Guide 16082011EH instead of ‘Alarm output2’. In the Active Alarm Groups tab are the configured and current alarmsĬlick on ‘Outputs’ tab and tick the boxes as detailed below then tick Apply then OK tabs. This slide is of version 3.2 Eltek How to Guide 16082011EH Then click on the ‘Get PC time & date’ button and click OK. Eltek How to Guide When you have finished, click Apply then OK 16082011EHĬlick on the ‘Adjust Date & Time’ tab in the Tools menu. Change the Install date and the Service date to the current date.

In the ‘Site’ tab, enter the Site JV number followed by the site name (e.g. In the ‘Company’ tab ’enter your company name’ followed by – KORDIA. This slide is of version 3.2 Eltek How to Guide 16082011EHĭisplays the working system of the ELTEK rack Return to Index This slide is of version 3.2 Return to IndexĮnter the password ‘709’ in the Security tab and press OK. Log in password is 0003 Eltek How to Guide 16082011EHĬlick on the ‘Login’ tab in the ‘Access’ menu. Step 2: Write the same number port on the Communication Port Windows that you got in FIND COM PORT Number. Step 1: Click on the Pen Icon to setup Communication Port Number. Setup Settings Step 2 Step 1 Will be the Same port number IMPORTANT: Click on the FIND COM PORT tab. Use 2.3 first, if not download the version being used on site by using the CD that is located on the shelf of the Eltek Rack. There are other software versions in circulation. Power Suite 2.3 is the software to use for the ELTEK RACK. To confirm connection is to right click on USB icon then connection should be highlighted and or displaying a tick on the left hand side of the description of the connection. RIGHT CLICK ON THE USB ICON THEN CHOOSE THE SILICON LABS ELTEK SMARTPACK. Setup of Laptop Connecting to the Controller Module Log into the Controller Module Main screen of Power System Configuring the Power System Configuring the Date and Time Active alarm Group Configuring Alarm Group Current event log Mains configuration Rectifier configuration Battery string configuration Log out procedure Disconnect from Controller unit